Content Source: 2021 RZR S4 1000 Owner’s Manual (9931549 R02) > Troubleshooting Chapter

IMPORTANT

The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle.Always follow the warnings and instructions in Owner's Manual.

Click the CONTENTS link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com

Engine Stops or Loses Power

Possible Cause Solution

Out of fuel

Refuel

Kinked or plugged fuel tank vent line or filter

Inspect and replace

Water is present in fuel

Replace with new fuel

Fouled or defective spark plugs

Inspect, clean and/or replace spark plug

Worn or defective spark plug wires

See your dealer

Incorrect spark plug gap or heat range

Set gap to specs or replace plug

Loose ignition connections

Check all connections and tighten

Low battery voltage

Recharge the battery to 12.8 VDC

Incorrect fuel

Replace with fresh recommended fuel

Clogged air filter

Inspect and replace

Clogged intake pre-filter

Inspect and clean (with soapy water) or replace

Other mechanical failure

See your dealer

Overheated engine

Clean radiator screen and core, clean engine exterior, check coolant level, see your dealer if condition persists


© Copyright Polaris Inc. All rights reserved.