/www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
Content Source: 2021 RZR Pro XP and Pro XP 4 Owner’s Manual (9931538 R01) > Maintenance Chapter
IMPORTANT |
The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle.Always follow the warnings and instructions in Owner's Manual. Click the CONTENTS link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com |
WARNING |
Improperly connecting or disconnecting battery cables can result in an explosion and cause serious injury or death. When removing the battery, always disconnect the negative (black) cable first. When reinstalling the battery, always connect the negative (black) cable last. |
NOTE |
If more amperage is required for high electrical loads, an additional battery can be added. |
WARNING |
An overheated battery may explode, causing severe injury or death. Always watch charging times carefully. Stop charging if the battery becomes very warm to the touch. Allow it to cool before resuming charging. |
IMPORTANT |
Do not connect the charging accessory to the 12V auxiliary outlet located inside the armrest storage compartment. The battery will receive no charge unless the charging accessory is connected to the outlet located on the dash as shown. |
State of Charge | Voltage (DC) | Action | Charge Time* |
100% | 12.8-13.0 volts | None, check monthly | None required |
75%-100% | 12.6-12.8 volts | May need slight charge, if no charge given, check in 2 weeks | 3-6 hours |
50%-75% | 12.3-12.6 volts | Needs charge | 5-11 hours |
25%-50% | 12.0-12.3 volts | Needs charge | At least 13 hours |
0%-25% | 12.0 volts or less | Needs charge | At least 20 hours |
* Using AGM specific charger at standard amps specified on top of battery |