Content Source: 2021 RZR XP Turbo S Velocity / XP Turbo S4 Velocity Owner’s Manual (9931525 R02) > Maintenance Chapter

IMPORTANT

The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle.Always follow the warnings and instructions in Owner's Manual.

Click the CONTENTS link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com

Demand Drive Unit (Front Gearcase)

Always check and change the fluid at the intervals outlined in the Periodic Maintenance Chart section. Refer to the Gearcase Specifications Chart section for recommended lubricants, capacities and torque specifications.

Fill Plug Location

Image

Drain Plug Location

Image

Demand Drive Fluid Check

The fill plug is located on the bottom right side of the demand drive unit. Maintain recommended fluid volume (280 ml).
  1. Position the vehicle on a level surface.
  2. Remove the fill plug. Check the fluid level.
  3. Add the recommended fluid to reach 280 ml capacity.
  4. Reinstall the fill plug. Torque to specification.

Demand Drive Fluid Change

The demand drive drain plug is located on the bottom of the gearcase.
  1. Remove the fill plug.
  2. Place a drain pan under the drain plug.
  3. Remove the drain plug. Allow the fluid to drain completely.
  4. Clean the drain plug.
  5. Reinstall the drain plug. Torque to specification.
  6. Add the recommended fluid (280 ml).
  7. Reinstall the fill plug. Torque to specification.
  8. Check for leaks. Discard used fluid properly and clean any excess oil residue.