Content Source: 2021 INDY VR1 / INDY XC / Switchback ASSAULT Owner’s Manual (9931271 R01) > Diagnostic Trouble Codes (DTC) Chapter

IMPORTANT

The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle.Always follow the warnings and instructions in Owner's Manual.

Click the CONTENTS link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com

Diagnostic Trouble Codes (DTCs) – Left Hand Controls

Matryx Left Hand Controls – Diagnostic Trouble Codes (DTCs)
SPN = Suspect Parameter Number / FMI = Failure Mode Indicator
SPN FMI P-Code Description Fault Setting Fault Healing

516360

0

C1106

Left Grip Heater Driver Over Temp

The temperature at left grip heater driver is greater than 60 DegC for 5 seconds

The temperature at left grip heater driver is less than 60 DegC for 5 seconds

5

C1107

Left Grip Heater Driver Under Current

The current at left grip heater driver is is less than 1A for 5 seconds

The current at left grip heater driver is is greater than 1.5A for 5 seconds

6

C1108

Left Grip Heater Driver Over Current

The current at left grip heater driver is is greater than 7A for 5 seconds

The current at left grip heater driver is is less than 6A for 5 seconds

31

C1109

Left Grip Heater Driver Internal Short

An internal short has been detected at the left grip heater driver. This would result in a 100% duty cycle output when not expected.

An internal short is not detected at the left grip heater driver.

516361

0

C110A

Right Grip Heater Driver Over Temp

The temperature at right grip heater driver is greater than 60 DegC for 5 seconds

The temperature at right grip heater driver is less than 60 DegC for 5 seconds

5

C110B

Right Grip Heater Driver Under Current

The current at right grip heater driver is is less than 1A for 5 seconds

The current at right grip heater driver is is greater than 1.5A for 5 seconds

6

C110C

Right Grip Heater Driver Over Current

The current at right grip heater driver is is greater than 7A for 5 seconds

The current at right grip heater driver is is less than 6A for 5 seconds

31

C110D

Right Grip Heater Driver Internal Short

An internal short has been detected at the right grip heater driver. This would result in a 100% duty cycle output when not expected.

An internal short is not detected at the right grip heater driver.

516362

0

C110E

Thumb Heater Driver Over Temp

The temperature at thumb heater driver is greater than 60 DegC for 5 seconds

The temperature at thumb heater driver is less than 60 DegC for 5 seconds

5

C110F

Thumb Heater Driver Under Current

The current at thumb heater driver is is less than 0.2A for 5 seconds

The current at thumb heater driver is is greater than 0.25A for 5 seconds

6

C1110

Thumb Heater Driver Over Current

The current at thumb heater driver is is greater than 1.4A for 5 seconds

The current at thumb heater driver is is less than 1.2A for 5 seconds

31

C1111

Thumb Heater Driver Internal Short

An internal short has been detected at the thumb heater driver. This would result in a 100% duty cycle output when not expected.

An internal short is not detected at the thumb heater driver.