The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle.Always follow the warnings and instructions in Owner's Manual. Click the CONTENTS link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com |
AC Output | Running (Rated) Watts | Additional Starting (Surge) Watts |
---|---|---|
Window AC - 10,000 BTU | 1200 | 3600 |
Window AC - 12,000 BTU | 3250 | 9750 |
Central AC - 10,000 BTU | 1500 | 4500 |
Central AC - 24,000 BTU | 3800 | 11400 |
Central AC - 40,000 BTU | 6000 | 18000 |
NOTICE |
Follow the air conditioner manufacturer's instructions for starting and restarting for proper operation. Some air conditioner
manufacturers offer a start capacitor as an extra cost option.
The lack of a start capacitor can cause the air conditioner to draw too high a starting current and overload the generator.
Contact your air conditioner dealer if you consistently have problems starting your air conditioner with the generator.
|