Content Source: Polaris Power® P3200iE Owner’s Manual (9931063 R03) > Operation Chapter

IMPORTANT

The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle.Always follow the warnings and instructions in Owner's Manual.

Click the CONTENTS link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com

Parallel Operation

WARNING
Only connect a parallel capable Polaris inverter generator with the approved parallel cable. Attempting to connect a different generator brand in parallel with your generator will void your warranty and could cause severe injury.
Do not start the generators before connecting the parallel cable. Running one generator with the cable connected will cause an overload and require an engine reset.
If the overload indicator light remains on after resetting the generator, stop the engine and wait five minutes before restarting.
NOTICE
  • For continuous operation, do not exceed the combined rated power of the paralleled generators.
  • Do not run the generators longer than 30 minutes at max output.
  • Always stop both engines before connecting or removing the parallel cable.
  • Always remove the parallel cable completely if operating a single unit.
To run generators in parallel, complete the following steps:

  1. Ensure both generators are off and fuel valves are closed.
  2. Connect the AC parallel cable to the parallel socket on each generator.
  3. Ensure all appliances are off and disconnected.
  4. Start each generator and then connect the appliance to the parallel cable.
  5. Turn on appliance.