The following battery
charging instructions apply only to the installation of a sealed battery.
Read all instructions before
proceeding with the installation of this battery.
The sealed battery
is already filled with electrolyte and has been sealed and fully charged at the factory. Never pry the sealing strip off
or add any other fluid to this battery.
The single most
important thing about maintaining a sealed battery is to keep it fully
charged. Since the battery is sealed
and the sealing strip cannot be removed, you must
use a voltmeter or multimeter to measure DC voltage.
WARNING |
An overheated battery may explode, causing severe injury or death.
Always watch charging times carefully. Stop charging if
the battery becomes very
warm to the touch. Allow it to cool before resuming charging. |
For a refresh charge,
follow all instructions carefully.
- Check the battery
voltage with a voltmeter or multimeter. A fully charged battery will
register 12.8 V or higher.
- If the voltage is
less than 12.8 volts, recharge the battery at 1.2 amps or less until
battery voltage is 12.8 or greater.
TIP |
When using an automatic charger, refer to the charger manufacturer's
instructions for recharging. When using a constant current
charger, use the guidelines
on the next page for recharging. |
Always verify battery
condition before and 1-2 hours after the end of charging.
State of Charge |
Voltage |
Action |
Charge Time*
|
*(Using constant
current charger @ standard amps specified on top of battery) |
100% |
12.8-13.0 volts |
None, check at 3 mos. from date of manufacture |
None required |
75%-100% |
12.5-12.8 volts |
May need slight charge, if no charge given,
check in 3 months |
3-6 hours |
50%-75% |
12.0-12.5 volts |
Needs charge |
5-11 hours |
25%-50% |
11.5-12.0 volts |
Needs charge |
At least 13 hours, verify state of charge |
0%-25% |
11.5 volts or less |
Needs charge with desulfating charger |