Demand Drive Unit (Front Gearcase)

Always check and change the fluid at the intervals outlined in the Periodic Maintenance Chart beginning on Maintenance Chart Tables. Refer to the Gearcase Specifications Chart on Gearcase Specification Chart for recommended lubricants, capacities and torque specifications.

Demand Drive Fluid Check

The fill plug is located on the bottom right side of the demand drive unit. Maintain the fluid level even with the bottom thread of the fill plug hole.
Image
  1. Position the vehicle on a level surface.
  2. Remove the fill plug. Check the fluid level.
  3. Add the recommended fluid to the bottom thread of the fill plug hole.
  4. Reinstall the fill plug. Torque to specification.

Demand Drive Fluid Change

The demand drive drain plug is located on the bottom of the gearcase.
Image
  1. Remove the fill plug.
  2. Place a drain pan under the drain plug.
  3. Remove the drain plug. Allow the fluid to drain completely.
  4. Clean the drain plug.
  5. Reinstall the drain plug. Torque to specification (listed in the Gearcase Specification Chart of this manual).
  6. Add the recommended fluid (listed in the Gearcase Specification Chart) to the bottom thread of the fill plug hole.
  7. Reinstall the fill plug. Torque to specification listed in the Gearcase Specification Chart).
  8. Check for leaks. Discard used fluid properly.