Charge Status Indicator Troubleshooting Guide

The code definitions provided are for informational purposes only. Please see your GEM dealer for diagnosis and repair.

# of Blinks

Code Definition

Solution

1

Battery high voltage

Check battery size and condition; reset charger (interrupt AC power for 15 seconds)

2

Battery low voltage

3

Charge time-out, battery pack not reaching required voltage, charger output reduced due to high temperatures

Check connections; operate charger at lower ambient temperature

4

Battery could not be trickle-charged to minimum voltage

Check battery for shorted or damaged cells

5

Charger shut down due to overheating

Ensure sufficient cooling air flow (remove the seat) and reset the charger (interrupt AC power for 15 seconds)

6

Charger internal fault

Reset charger (interrupt AC power for 15 seconds); return to qualified service provider if fault persists


© Copyright Polaris Industries Inc. All rights reserved.